In mobile and rotating machinery, power cables are subjected to tension, torsion, repeated bending and abrasion. Each cycle shortens the cable’s service life, increases the risk of machine downtime and requires unplanned maintenance, with costs exceeding those of the cable itself. The solution depends on the type of movement: the cable reel manages the linear movement of a mobile unit, while the slip ring transfers power and signals from a stationary part to a rotating one.
TER manufactures both solutions for lifting equipment and industrial automation.
To reduce industrial cable wear, a spring-driven cable reel is chosen when the mobile unit moves along a path and the cable must remain under controlled tension, a motor-driven cable reel when higher currents are required, up to 650 A, and a slip ring when the powered part rotates. Current, voltage, control signals, degree of protection and temperature are key factors.
Why cables wear out
A cable left on the ground is crushed and dragged. A suspended cable undergoes continuous bending at the same points. On a rotating part, the cable twists until it breaks. The cable reel retrieves the cable and keeps it properly arranged, while the slip ring transfers current without cables being subjected to twisting: in both cases, the stresses that cause cable wear are eliminated. Fewer pulls, less torsion and less contact with the floor mean intact cable sheaths, protected conductors and much longer replacement intervals.

Apollo cable reels: spring-Driven or motor-driven
Apollo is available in two versions, spring-driven or motor-driven.
The spring-driven cable reel uses Archimedean spiral springs, is designed for effective and economical solutions, achieves IP67, operates from -20 °C to +60 °C (down to -40 °C on request) and handles currents up to 250 A.
The motor-driven cable reel uses a three-phase torque motor, has a degree of protection of IP65, operates from -15 °C to +40 °C and handles currents up to 400 A.
Both versions supply control signals, data, electrical power or fluids such as compressed air, gas and hydraulic oils. On request, they can be equipped with limit switches, anti-condensation heaters, shock-absorbing springs and bidirectional cable guides. Marine versions in AISI 316L stainless steel and ATEX versions are available. For complete specifications, see the Apollo cable reels page.
Slip rings: power and signals on rotating parts
Slip rings transfer current from a stationary part to a rotating one. The 50A slip ring has up to 16 power rings rated at 50 A, paired with phosphor bronze brushes (graphite brushes available on request for longer service life), powers the motors of cranes and cable reeling machines, has an IP22 degree of protection and reaches 3 revolutions per minute.
Pegasus transmits AC and DC current together with analog and digital control signals, supports the main industrial network and bus protocols and reaches 30 revolutions per minute. It is available in several current ratings and, on request, with hydraulic joints. The slip ring integrated into Apollo accommodates up to 42 power rings. Discover the Pegasus slip ring on the dedicated page.
How to choose: the key parameters
The starting point is the type of movement: linear travel requires a cable reel, while rotation requires a slip ring. Next, check current and voltage, the number of signal circuits, rotation speed, degree of protection and operating temperature. In the presence of salt spray, explosive atmospheres or low temperatures, it is advisable to specify marine, ATEX or low-temperature versions from the outset. It is also advisable to provide a current reserve above the rated load and plan access to the slip ring or cable reel for periodic maintenance, in order to reduce intervention times. Electrical equipment operating between 50 and 1000 V AC falls within the scope of the Low Voltage Directive 2014/35/EU.
Frequently asked questions about cable reels and slip rings
Is a spring-driven or motor-driven cable reel better?
The spring-driven model is designed for effective and economical solutions and handles currents up to 250 A. The motor-driven model, equipped with a three-phase torque motor, handles currents up to 400 A.
When Is a Slip Ring Needed Instead of a Cable Reel?
When the powered part rotates, as in tower cranes or amusement rides. The slip ring transmits power and signals without cables being subjected to twisting.
Can a slip ring also transmit data?
Yes. Pegasus transmits analog and digital control signals and supports the main industrial network and bus protocols.
Do slip ring brushes need to be inspected?
Yes, because they are components subject to wear. In the 50A slip ring, they are made of phosphor bronze and, on request, graphite for longer service life.
Technical Section for Experts
Slip Ring Inspection Procedure:
Disconnect the power supply and verify the absence of voltage. Check the condition of the brushes and the cleanliness of the rings. In the 50A slip ring, verify that the ventilation openings and the three condensate drainage holes are not obstructed. Check the tightness of the terminals and ring cable lugs. Restore the power supply and check the continuity of each circuit with the rotating part moving slowly, recording any signal interruptions for comparison with subsequent inspections.
Conclusions
Reducing cable wear means choosing the solution suited to the type of movement: the spring-driven cable reel or motor-driven cable reel for mobile units, and the slip ring for rotating parts. TER offers both product families, with versions for harsh, marine and ATEX environments.